19 Top Current Clamps

 

Seaward 396A951 ACDC Current Clamp

Seaward 396A951 AC/DC Current Clamp

Seaward 396A951 AC/DC Current Clamp - Works with hantek 1008c or any oscilloscope. Ac/dc frequency range up to 20 khz. Limited us inventory in ca. Works with multi-meter with bnc 2 banana plug adapter. Effective measurement range 20ma to 650a dc.

 

Fluke i1000s 1000 Amp AC Current Clamp

Fluke i1000s 1000 Amp AC Current Clamp

Fluke i1000s 1000 Amp AC Current Clamp - Insulated bnc connector and reinforced coaxial cable for connecting to an oscilloscope. Clamp measures current in a cable with a maximum diameter of 54mm without touching or interrupting the circuit. Meets iec safety standards 61010-1 and 61010-02-032, and is rated for cat iv installations to 300v and cat iii installations to 600v. Passive filter helps eliminate noise and ring on rapidly rising di/dt waveforms for accurate screen displays. Current probe measures ac current from 100ma to 1,000 amp and frequency from 5hz to 100hz and is for use with oscilloscopes (sold separately) in industrial or power environments.

 

Hantek CC-650 ACDC Current Clamp Meter Multimeter with BNC Connector

Hantek® CC-650 AC/DC Current Clamp Meter Multimeter with BNC Connector

Hantek® CC-650 AC/DC Current Clamp Meter Multimeter with BNC Connector - And if connect to an oscilloscope by bnc type connector, you’re able to observe the current waveforms if connect to a multimeter by banana type connector, you can obtain the current data. General description ac/dc current clamp, 400hz bandwidth, 1mv/10ma, 650a it is a transducer which allows your multimeter to measure current data and enable your oscilloscope to measure the current waveforms. Detailed description ac/dc current clamp, 400hz bandwidth, 1mv/10ma, 650a feature ac/dc frequency range up to 400hz effective measurement range 20ma to 650a dc it is a transducer which allows your multimeter to measure current data and enable your oscilloscope to measure the current waveforms. Application power circuit measurement and malfunction analysis motor drive of frequency converter (or other electronics) measurement power electronics equipments measurement. Its current transducer is composed by permalloy and hall element, which linearly transform the ac or dc current to ac or dc current voltage.

 

Amprobe CT235A Clamp Accessory Current Transformer

Amprobe CT235A Clamp Accessory Current Transformer

Amprobe CT235A Clamp Accessory Current Transformer - Meets applicable european conformity (ce) directives. Clamp with 12″ (31 mm) jaw opening measures current without touching or interrupting the circuit. Converts high-current signal to low-level millivolt signal so it can be read by a testing device. Measures alternating current (ac) and direct current (dc) to 1,000 amp. Zero adjust knob. Zero adjust knob allows operator to compensate for changes in output voltage due to environmental conditions. Ac/dc current clamp, 1000 a. Converts high current to a low level millivolt signal.

 

Fluke I5A50A CLAMP PQ1 1 Phase Mini Current Clamp Set for Power Quality Logger 5A50A Current

Fluke I5A/50A CLAMP PQ1 1 Phase Mini Current Clamp Set for Power Quality Logger, 5A/50A Current

Fluke I5A/50A CLAMP PQ1 1 Phase Mini Current Clamp Set for Power Quality Logger, 5A/50A Current - Fluke 1 phase mini current clamp set for power quality logger. I5a/50a current.

 

Fluke I3000S Very High AC Current Clamp 600V AC Voltage 3000A AC Current

Fluke I3000S Very High AC Current Clamp, 600V AC Voltage, 3000A AC Current

Fluke I3000S Very High AC Current Clamp, 600V AC Voltage, 3000A AC Current - The clamp is optimized for measurement on power distribution systems. Fluke current clamps are the ideal tools to extend the current ranges of fluke tools. Clamp-on ac current clamp for use with oscilloscopes and multimeters with banana input using the supplied dual banana to bnc adapter. 1 year warranty. Cat iii 600v safety rating.

 

Fluke I1A10A CLAMP PQ1 1 Phase Mini Current Clamp Set for Power Quality Logger 1A10A Current

Fluke I1A/10A CLAMP PQ1 1 Phase Mini Current Clamp Set for Power Quality Logger, 1A/10A Current

Fluke I1A/10A CLAMP PQ1 1 Phase Mini Current Clamp Set for Power Quality Logger, 1A/10A Current - 1a/10a current. Fluke 1 phase mini current clamp set for power quality logger.

 

Fluke I1A10A CLAMP PQ4 4 Phase Mini Current Clamp Set for Power Quality Logger 1A10A Current

Fluke I1A/10A CLAMP PQ4 4 Phase Mini Current Clamp Set for Power Quality Logger, 1A/10A Current

Fluke I1A/10A CLAMP PQ4 4 Phase Mini Current Clamp Set for Power Quality Logger, 1A/10A Current - I1a/10a current. Fluke 4 phase mini current clamp set for power quality logger.

 

Fluke I200S AC Current Clamp 600V AC Voltage 20A and 200A Current

Fluke I200S AC Current Clamp, 600V AC Voltage, 20A and 200A Current

Fluke I200S AC Current Clamp, 600V AC Voltage, 20A and 200A Current - Take accurate current readings without breaking the circuit, maximum conductor diameter 20mm, cat iii 600v safety rating. Included adapter for dmm’s. Two ranges 20a and 200a, 10 or 100 mv/amp output. Companion to your scopemeter, power quality meter or digital multimeter to measure up to 200 a ac. 1 year warranty.

 

Amprobe LH41A Low Current Clamp-On Ammeter

Amprobe LH41A Low Current Clamp-On Ammeter

Amprobe LH41A Low Current Clamp-On Ammeter - Average-sensing meter provides accurate readings when measuring linear loads, where the current or voltage has a sinusoidal waveform. Digital clamp meter measures alternating current (ac) or direct current (dc) to 40 amp. Zero adjust function compensates for changes in output voltage due to environmental conditions. Hall effect clamp with 078″ (28 mm) jaw opening measures current without touching or interrupting the circuit. Meets international electrotechnical commission (iec) safety standard 61010 and is certified for category iii installations up to 300v.

 

Fluke TPS CLAMP 50A5A Clip On Current Transformer 005A-5A Current 40 Hz to 10 kHz Frequency

Fluke TPS CLAMP 50A/5A Clip On Current Transformer, 0.05A-5A Current, 40 Hz to 10 kHz Frequency

Fluke TPS CLAMP 50A/5A Clip On Current Transformer, 0.05A-5A Current, 40 Hz to 10 kHz Frequency - Intrinsic error 0. 5 percent. Jaw opening less-than 15-millimeters diameter or 15-millimeters by 17-millimeters bus bars. 5 a to 50 a. Phase error 0. Peak current for sinusoidal currents 18 a and 180 a. Measuring range selectable per software 0. Fluke a clip-on current transformer. Frequency range 40 hz to 10 khz. 05 a to 5 a and 0. Operating voltage 300 v cat iv. 5 degree.

 

Fluke I5S-PR Clamp On Current Transformer for 1750 3 Phase Power Quality Recorder 5A Current

Fluke I5S-PR Clamp On Current Transformer for 1750 3 Phase Power Quality Recorder, 5A Current

Fluke I5S-PR Clamp On Current Transformer for 1750 3 Phase Power Quality Recorder, 5A Current - Fluke 5a clamp-on current transformer for 1750 3 phase power quality recorder.

 

Amprobe CT237B ACDC Current Clamp Adapter 05 to 200A Current Range mV Output 50Hz - 10kHz Frequency Range

Amprobe CT237B AC/DC Current Clamp Adapter, 0.5 to 200A Current Range, mV Output, 50Hz – 10kHz Frequency Range

Amprobe CT237B AC/DC Current Clamp Adapter, 0.5 to 200A Current Range, mV Output, 50Hz – 10kHz Frequency Range - Hall effect clamp with 075″ (19 mm) jaw opening measures current without touching or interrupting the circuit. Meets applicable european conformity (ce) directives. Zero adjust knob allows operator to compensate for changes in output voltage due to environmental conditions. Measures alternating current (ac) and direct current (dc) to 200 amp. Converts high-current signal to low-level millivolt signal so it can be read by a testing device.

 

Fluke I5S AC Current Clamp 600V AC Voltage 5A AC Current

Fluke I5S AC Current Clamp, 600V AC Voltage, 5A AC Current

Fluke I5S AC Current Clamp, 600V AC Voltage, 5A AC Current - With bnc adapter. Measures 116mm length by 43mm width by 23mm height. Maximum non-destructive current 70a. Cat iii 600 v (for insulated conductors only). Lowest measurable current 10ma. Take accurate readings without breaking the circuit. Output cable length 2. Useable frequency 40 hz to 5 khz. Continuous current range 10ma to 6a. Input load impedance greater than 1 mega ohm in parallel with up to 47 pf. Output levels 400 mv/a. 7 percent to accuracy. Expand the use of your fluke 430 series power quality tool or scopemeter test tool with this 5a ac current clamp, specially configured to provide good accuracy at low levels e. Maximum voltage 600v ac. Safety cat iii 600v per iec/en61010-1, pollution degree 2. G. Nominal current range 5a. Crest factor less than or equal to 3, add 0. While taking measurements on secondary current transformers. Maximum conductor diameter 15mm. Basic accuracy 10ma to 1a 1 percent + 5 ma, 1a to 5a 1 percent. Compact shape makes transporting and storing convenient. 5m.

 

Fluke I30S ACDC Current Clamp 300V ACDC Voltage 30A DC 20A AC rms Current

Fluke I30S AC/DC Current Clamp, 300V AC/DC Voltage, 30A DC, 20A AC rms Current

Fluke I30S AC/DC Current Clamp, 300V AC/DC Voltage, 30A DC, 20A AC rms Current - 14″ crest factor. Current clamp is based on hall effect technology. Use in measurement of both dc and ac current. 100 mv/a output sensitivity. It may be used in conjunction with oscilloscopes and other suitable recording instruments for accurate non-intrusive current measurement.

 

Hantek ACDC Current Clamp CC 65 Up To 20 kHz 20mA To 65A DC

Hantek® AC/DC Current Clamp CC 65 Up To 20 kHz 20mA To 65A DC

Hantek® AC/DC Current Clamp CC 65 Up To 20 kHz 20mA To 65A DC - Ac/dc frequency range up to 20 khz effective measurement range 20ma to 650a dc it is a transducer which allows your multimeter to measure current data and enable your oscilloscope to measure the current waveforms. Captured conductor size9mm maximum low battery indictorred led lighting operating temperature0℃to 50℃70% r. Battery type9v dc, neda 1604, 6f22,0006p battery life100 hours typical with alkaline weight250 gm typical dimensions195mm(h) x 70mm(w) x 33mm(d) outputsupplied with coil cable with straight banana plug or bnc plug. Power circuit measurement and malfunction analysis motor drive of frequency converter (or other electronics) measurement power electronics equipments measurement. And if connect to an oscilloscope by bnc type connector, youˇre able to observe the current waveforms if connect to a multimeter by banana type connector, you can obtain the current data. Storage temperature-20℃ to +70℃, 80% r. Its current transducer is composed by permalloy and hall element, which linearly transform the ac or dc current to ac or dc current voltage. H. H.

 

Fluke I20200A CLAMP PQ3 3 Phase Mini Current Clamp Set for Power Quality Logger 20200A Current

Fluke I20/200A CLAMP PQ3 3 Phase Mini Current Clamp Set for Power Quality Logger, 20/200A Current

Fluke I20/200A CLAMP PQ3 3 Phase Mini Current Clamp Set for Power Quality Logger, 20/200A Current - I20/200a current. Fluke 3 phase mini current clamp set for power quality logger.

 

Fluke I2000 FLEX Flexible AC Current Clamp 600V ACDC Voltage 2000A AC Current

Fluke I2000 FLEX Flexible AC Current Clamp, 600V AC/DC Voltage, 2000A AC Current

Fluke I2000 FLEX Flexible AC Current Clamp, 600V AC/DC Voltage, 2000A AC Current - Three ranges 20a, 200 a and 2000 a, 100 mv/a, 10 mv/a and 1 mv/a output. Ideal for current measurement on thick and hard to reach conductors without breaking the circuit. Maximum conductor diameter 178mm. Cat iii 600v safety rating. 1 year warranty.

 

Fluke i400s 400 Amp AC Current Clamp with BNC Connector

Fluke i400s 400 Amp AC Current Clamp with BNC Connector

Fluke i400s 400 Amp AC Current Clamp with BNC Connector - Soft non-slippery overmold handle. Take accurate current readings without breaking the circuit. Companion to your scope or power quality meter to measure up to 400 a ac. Specially designed to offer maximum utility in a compact shape. Only current clamp available with a cat iv 600 v / cat iii 1000 v safety rating.





We are a participant in the Amazon Services LLC Associates Program, an affiliate advertising program designed to provide a means for us to earn fees by linking to Amazon.com and affiliated sites.